CYBERSCAN CON 11 PORTABLE

Posted by on Apr 11, 2017 in Brand - Eutech, Product - Conductivity Meter, Products

CYBERSCAN CON 11 PORTABLE

CYBERSCAN CON 11 PORTABLE Onductivity Range : 0 to 199.9 mS/ cm TDS Range : 0 to 99.9 ppt Resolution & Accuracy : 0.05% Full Scale & Temp Range : -10.0 to 110.0 ° C ( Meter) Resolution & Accuracy : 0.1 ° C & ± 0.5 ° C Calibration for Conductivity : Automatic ( single or multi-point up to 4 points) / Manual ( up to 5 points) Calibration for TDS : Manual ( up to 5 points – 1 per range) No. of Calibration Points : Up to 5 points ( 1 per range) Temperature...

Read More »

COND 6+ PORT

Posted by on Apr 11, 2017 in Brand - Eutech, Product - Conductivity Meter, Products

COND 6+ PORT

COND 6+ PORT Conductivity Range : 0 – 199.9 mS/ cm Resolution & Accuracy : 0.05% full scale & ± 1% full scale + 1 LSD Calibration Points : 4 ( 1 per range) auto; 5 ( 1 per range) manual Temperature Range : 0 to 80.0 ° C ( 32 to 176 ° F) Resolution & Accuracy : 0.1 ° C ( 0.1 ° F) & ± 0.5 ° C ( ± 0.9 ° F) Temperature Compensation : Automatic / Manual ( 0 to 80 ° C) Cell Constant : 0.1, 1.0, 10.0 ( selectable) Temperature Coefficient : 0.0% to 3.0% Temperature...

Read More »

PHIONLAB EC10 PORTABLE CONDUCTIVITY METER

Posted by on Apr 11, 2017 in Product - Conductivity Meter, Products

PHIONLAB EC10 PORTABLE CONDUCTIVITY METER

Conductivity range 0-20.00, 200.0, 2000 µ s/ cm ; 20.00, 200.0 mS/ cm TDS range 0-10.00, 100.0, 1000 mg/ L : 10.00, 100 g/ L Resistivity range 0-100 M© Salinity range 0-100 ppt Accuracy & Resolution ± 1% Full Scale & 0.5 Full Scale Temp. Compensation 0-50° C ( Automatic/ Manual) Calibration ( Automatic) Single Point( 84 µ S/ 1413 µ s/ 12.88 mS/ 111.9 Ms) Cell Constant ( K) 0.1, 1.0, 10.0 Temp. Coefficient 0 – 9.99% TDS Factor 0.0 – 10.0 Reference Temperature 25, 20...

Read More »

LDS-1G

Posted by on Apr 11, 2017 in Brand - China, Product - Grain Moisture tester, Products

LDS-1G

LDS-1G Test object: foodstuff and other nonmetal grain sample, such as rice, wheat, maize, so bean and rapeseed. Test range: 3 — 35% Repeat error: equal or less than 0.2% Test error: equal or less than 0.5% ( mainly moisture range) Test time: equal or less than 10s Sample: weight 150 gram ( excluding the special sample) Power supply: four # 5 dry battery or DC Adaptor Automation switch off: the instrument will be switched off automatically if there is operation within 3...

Read More »

Autoclave All American 75X

Posted by on Apr 10, 2017 in Brand - All American, Product - Autoclave, Products

Autoclave All American 75X

Descriptions: The All American Electric Sterilizer 75X-240V is a complete, self-contained unit with an immersion heating element, automatic thermostatic control, automatic release valve, and pilot light. It connects to any outlet, is ready for use instantly, and ensures complete, efficient sterilization. Only All American Sterilizers feature an exclusive, precision machined “Metal-to-Metal” sealing system. Positive action clamping locks align the cover to the base forming a...

Read More »